4 research outputs found

    Coronary atherosclerosis and wall shear stress: Towards application of CT angiography

    Get PDF
    __Abstract__ Vulnerable plaques are characterized by the presence of a large lipid pool, which is separated from the lumen by a thin fibrous cap, often infiltrated by macro phages [Schaar-04]. Rupture of this fibrous cap is generally regarded as one of the main underlying causes of cardiovascular events [Fa!k-95]. Rupture occurs when the stresses in the cap of the plaque exceed the strength of the cap [Lee-93]. The composition of the plaque plays a crucial role in the rupture process: it determines how blood pressure is translated into stresses in the wall, and composition also determines the strength of the tissue [Loree-94, Holzapfel-05]

    3D fusion of intravascular ultrasound and coronary computed tomography for in-vivo wall shear stress analysis: A feasibility study

    Get PDF
    Wall shear stress, the force per area acting on the lumen wall due to the blood flow, is an important biomechanical parameter in the localization and progression of atherosclerosis. To calculate shear stress and relate it to atherosclerosis, a 3D description of the lumen and vessel wall is required. We present a framework to obtain the 3D reconstruction of human coronary arteries by the fusion of intravascular ultrasound (IVUS) and coronary computed tomography angiography (CT). We imaged 23 patients with IVUS and CT. The images from both modalities were registered for 35 arteries, using bifurcations as landmarks. The IVUS images together with IVUS derived lumen and wall contours were positioned on the 3D centerline, which was derived from CT. The resulting 3D lumen and wall contours were transformed to a surface for calculation of shear stress and plaque thickness. We applied variations in selection of landmarks and investigated whether these variations influenced the relation between shear stress and plaque thickness. Fusion was successfully achieved in 31 of the 35 arteries. The average length of the fused segments was 36.4 ± 15.7 mm. The length in IVUS and CT of the fused parts correlated excellently (R2= 0.98). Both for a mildly diseased and a very diseased coronary artery, shear stress was calculated and related to plaque thickness. Variations in the selection of the landmarks for these two arteries did not affect the relationship between shear stress and plaque thickness. This new framework can therefore successfully be applied for shear stress analysis in human coronary arteries

    Plaque and shear stress distribution in human coronary bifurcations: A multislice computed tomography study

    No full text
    Aims: Early atherosclerosis is located in low wall shear-stress (WSS) regions, however plaques are also found in the high WSS sensing flow divider walls of coronary bifurcations. We assessed the plaque distribution and morphology near bifurcations n

    Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms

    No full text
    Efficiently obtaining a reliable coronary artery centerline from computed tomography angiography data is relevant in clinical practice. Whereas numerous methods have been presented for this purpose, up to now no standardized evaluation methodology has been published to reliably evaluate and compare the performance of the existing or newly developed coronary artery centerline extraction algorithms. This paper describes a standardized evaluation methodology and reference database for the quantitative evaluation of coronary artery centerline extraction algorithms. The contribution of this work is fourfold: (1) a method is described to create a consensus centerline with multiple observers, (2) well-defined measures are presented for the evaluation of coronary artery centerline extraction algorithms, (3) a database containing 32 cardiac CTA datasets with corresponding reference standard is described and made available, and (4) 13 coronary artery centerline extraction al
    corecore